Pre-requisites
Download and install WSO2 WSAS-3.1.1
Persistent implementation of WS-RM will be supported in most of the popular DBMSs. However, I will use MySQL server 5.* in this demonstration. Therefore, install and configure MySQL.
Step 1
As the first step, we need to create the persistent storage which is going to be used in reliable message transmission. Lets create a data base and the necessary table as follows.
mysql>create database SANDESHA_DB;
mysql>use SANDESHA_DB;
mysql>create table wsrm_sender (
message_id varchar(255) not null,
message_context_ref_key varchar(255),
internal_sequence_id varchar(255),
sequence_id varchar(255),
to_address varchar(255),
inbound_sequence_id varchar(255),
send smallint,
sent_count integer,
message_number bigint,
resend smallint,
time_to_send bigint,
message_type integer,
last_message smallint,
inbound_message_number bigint,
transport_available smallint,
flags integer,
primary key (message_id)
);
mysql>create table wsrm_rmd (
sequence_id varchar(255) not null,
to_epr_addr varchar(255),
to_epr blob,
reply_to_epr_addr varchar(255),
reply_to_epr blob,
acks_to_epr_addr varchar(255),
acks_to_epr blob,
rm_version varchar(255),
security_token_data varchar(255),
last_activated_time bigint,
closed smallint,
terminated_flag smallint,
polling_mode smallint,
service_name varchar(255),
flags integer,
reference_message_key varchar(255),
highest_in_message_id varchar(255),
last_in_message_id varchar(255),
server_completed_messages blob,
outof_order_ranges blob,
to_address varchar(255),
outbound_internal_sequence varchar(255),
next_msgno_to_process bigint,
highest_in_message_number bigint,
rmd_flags integer,
primary key (sequence_id)
);
mysql>create table wsrm_rms (
create_seq_msg_id varchar(255) not null,
sequence_id varchar(255),
to_epr_addr varchar(255),
to_epr blob,
reply_to_epr_addr varchar(255),
reply_to_epr blob,
acks_to_epr_addr varchar(255),
acks_to_epr blob,
rm_version varchar(255),
security_token_data varchar(255),
last_activated_time BIGINT,
closed smallint,
terminated_flag smallint,
polling_mode smallint,
service_name varchar(255),
flags integer,
id bigint,
internal_sequence_id varchar(255),
create_sequence_msg_store_key varchar(255),
reference_msg_store_key varchar(255),
last_send_error blob,
highest_out_relates_to varchar(255),
client_completed_messages blob,
transport_to varchar(255),
offered_endpoint varchar(255),
offered_sequence varchar(255),
anonymous_uuid varchar(255),
last_send_error_timestamp bigint,
last_out_message bigint,
highest_out_message_number bigint,
next_message_number bigint,
terminate_added smallint,
timed_out smallint,
sequence_closed_client smallint,
expected_replies bigint,
soap_version integer,
termination_pauser_for_cs smallint,
avoid_auto_termination smallint,
rms_flags integer,
primary key (create_seq_msg_id)
);
mysql>create table wsrm_invoker (
message_context_ref_key varchar(255) not null,
sequence_id varchar(255),
context blob,
msg_no bigint,
flags integer,
PRIMARY KEY (message_context_ref_key)
);
mysql>create table wsrm_msgctx (
ctx_key varchar(255) not null,
ctx blob,
PRIMARY KEY (ctx_key)
);
Note: From WSAS-3.2.0 onwards, the following columns must be added to the wsrm_rms table in addition to the columns specified above.
offered_endpoint_epr_addr varchar(255),
offered_endpoint_epr varchar(255),
reallocated integer,
internalSeqIDOfSeqUsedForReallocation varchar(255),
Step 2
Since we are going to establish a JDBC connection to a MySQL DB, copy mysql jdbc driver to WSAS_HOME/repository/components/lib and restart WSAS
Log in to WSAS management console and click on modules -->list. Click on configure link of the sandesha2 module.
By default, WSO2 WSAS uses an inmemory implementation of WS-RM. You can change it to persistent by changing Storage Manager property. Configure the rest of the persistent storage details as follows.
Connection String - jdbc:mysql://localhost:3306/SANDESHA_DBStep 3
Driver Name - com.mysql.jdbc.Driver
Username - your mysql username
Password - your mysql password
Now, you have enabled persistent RM in WSO2 WSAS. However, due to a bug in the latest WSAS releases, you should update the following property in WSAS_HOME/conf/axis2.xml
<parameter name="Sandesha2StorageManager">persistent</parameter>
Make sure to restart WSAS after configuring the above element in axis2.xml
Step 4
Now, you are ready to send requests to a service hosted in WSAS through RM and verify persistent RM. In order to do that, engage sandesha2 module in a service and send series of requests (say 100 requests) using a RM client (I assume you are familiar with sending soap messages with RM headers. I will publish a separate post on complete RM client-server invocation soon). After transmitting 30 requests, shutdown WSAS and restart. You will notice that after the server is restarted, the message transmission will be resumed from the message no: 31
If you have any issues with the steps given above, please drop me a mail.